W-Liner | Water
After trenchless rehabilitation with the W-Liner, pressure pipes can once again transport drinking water and other types of water safely and without loss.
For application in the water sector, the inner and outer layers of the liner consist of polyethylene (PE).
The W-Liner satisfies the highest requirements for drinking water and is certified in accordance with globally reputable standards such as KTW-BWGL, DVGW Technical Standard W 270, ANSI/NSF/CAN 61, BS 6920, AS/NZS 4020 and many more.
The Primus Line W-Liner is ideal for:
- Drinking water
- Fire water
- Industrial water
- Sea water
- Process water
- Residential wastewater
- Industrial wastewater
- Treated wastewater
- Brine
Other media only after detailed examination and approval by our technical department.
Additional information on the variants
1 determined according to ISO 9080 for water at 68 °F
2 liner labeling may differ due to different calculation basis
Variants
Type ND
Variant | Outer diameter | Wall thickness | Inner diameter | Burst pressure | Operating pressure¹⁺² | Weight |
---|---|---|---|---|---|---|
ND 150 | 5.28 in | 0.24 in | 4.80 in | 914 psi | 363 psi | 1.4 lbs/ft |
ND 150 SD | 5.91 in | 0.24 in | 5.43 in | 783 psi | 290 psi | 1.6 lbs/ft |
ND 200 | 7.20 in | 0.24 in | 6.73 in | 682 psi | 261 psi | 2.0 lbs/ft |
ND 203 SD | 8.07 in | 0.24 in | 7.60 in | 609 psi | 232 psi | 2.2 lbs/ft |
ND 250 | 9.33 in | 0.24 in | 8.86 in | 551 psi | 218 psi | 2.6 lbs/ft |
ND 261 SD | 10.28 in | 0.24 in | 9.80 in | 435 psi | 174 psi | 2.8 lbs/ft |
ND 300 | 11.18 in | 0.24 in | 10.71 in | 435 psi | 174 psi | 3.1 lbs/ft |
ND 350 | 12.28 in | 0.24 in | 11.81 in | 478 psi | 191 psi | 3.4 lbs/ft |
ND 400 | 13.94 in | 0.24 in | 13.46 in | 435 psi | 174 psi | 3.9 lbs/ft |
Type HD
Variant | Outer diameter | Wall thickness | Inner diameter | Burst pressure | Operating pressure¹⁺² | Weight |
---|---|---|---|---|---|---|
HD 150 SD | 6.10 in | 0.31 in | 5.47 in | 2,987 psi | 1,189 psi | 2.2 lbs/ft |
HD 200 | 7.36 in | 0.31 in | 6.73 in | 2,509 psi | 1,001 psi | 2.7 lbs/ft |
HD 250 | 9.49 in | 0.31 in | 8.86 in | 1,856 psi | 740 psi | 3.6 lbs/ft |
HD 300 | 11.34 in | 0.31 in | 10.71 in | 1,595 psi | 638 psi | 4.3 lbs/ft |
HD 400 | 14.06 in | 0.31 in | 13.43 in | 1,189 psi | 464 psi | 5.4 lbs/ft |
Type MD
Variant | Outer diameter | Wall thickness | Inner diameter | Burst pressure | Operating pressure¹⁺² | Weight |
---|---|---|---|---|---|---|
MD 150 | 5.28 in | 0.24 in | 4.80 in | 2,030 psi | 812 psi | 1.5 lbs/ft |
MD 150 SD | 5.91 in | 0.24 in | 5.43 in | 1,740 psi | 696 psi | 1.6 lbs/ft |
MD 200 | 7.20 in | 0.24 in | 6.73 in | 1,450 psi | 580 psi | 2.0 lbs/ft |
MD 203 SD | 8.07 in | 0.24 in | 7.60 in | 1,218 psi | 479 psi | 2.3 lbs/ft |
MD 250 | 9.33 in | 0.24 in | 8.86 in | 1,088 psi | 435 psi | 2.7 lbs/ft |
MD 261 SD | 10.28 in | 0.24 in | 9.80 in | 928 psi | 363 psi | 2.9 lbs/ft |
MD 300 | 11.18 in | 0.24 in | 10.71 in | 928 psi | 363 psi | 3.2 lbs/ft |
MD 350 | 12.28 in | 0.24 in | 11.81 in | 725 psi | 290 psi | 3.5 lbs/ft |
MD 400 | 13.94 in | 0.24 in | 13.46 in | 667 psi | 261 psi | 4.1 lbs/ft |
MD 450 | 16.06 in | 0.24 in | 15.59 in | 580 psi | 232 psi | 4.7 lbs/ft |
MD 500 | 17.87 in | 0.24 in | 17.40 in | 580 psi | 232 psi | 5.2 lbs/ft |